Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Rev. bras. ortop ; 56(6): 790-795, Nov.-Dec. 2021. graf
Article in English | LILACS | ID: biblio-1357137

ABSTRACT

Abstract Objective The present study aimed to evaluate and compare the total surgical procedure time and intraoperative X-ray exposure during different techniques for fixation of transtrochanteric fractures of the femur in elderly patients, using extramedullary and intramedullary methods based on cephalic traction screws. Methods The Orthopedics and Traumatology Service from our hospital evaluated 107 patients with transtrochanteric fractures, including 34 males and 73 females, with age ranging from 61 to 101 years old. Fracture fixation was performed with a dynamic hip system (DHS) in 21 patients, a standard proximal femoral nail (PFN) in 55 subjects, and a standard gamma nail in 31 patients. All procedures were performed by the same surgeon and his team of nursing assistants, along with the same radiology technician using the same image intensifier. Total surgery time (in minutes) and X-ray emission (in centigrays [cGy]) were evaluated. Results Transtrochanteric fracture fixation with PFN provides a significantly shorter surgical time (p = 0.013) in comparison to the 2 other techniques. Intraoperative exposure to X-rays was significantly lower when using DHS (p = 0.015) as a fixation method when compared with gamma nail and PFN. Conclusion Although PFN resulted in the shortest surgical time, DHS was associated with the lowest X-ray exposure levels within the studied sample.


Resumo Objetivo Avaliar e comparar o tempo total do procedimento cirúrgico e a exposição ao raio X no intraoperatório em diferentes técnicas de fixação das fraturas transtrocanterianas do fêmur em pacientes idosos, utilizando técnicas extramedulares e intramedulares baseadas em parafuso de tração cefálico. Métodos Foram avaliados no serviço de ortopedia e traumatologia do nosso hospital 107 pacientes com fraturas transtrocanterianas, sendo 34 do sexo masculino e 73 do sexo feminino, com idade mínima de 61 anos e máxima de 101 anos. As fraturas fixadas, utilizando a técnica com dynamic hip system (DHS, na sigla em inglês) somaram 21 pacientes; em 55 pacientes, foi utilizado o proximal femur nail (PFN, na sigla em inglês) standard; e em 31 idosos, foi optado pelo uso do gama nail standard. Todos os procedimentos foram realizados pelo mesmo cirurgião acompanhado de sua equipe de auxiliares de enfermagem, assim como pelo mesmo técnico de radiologia manuseando o mesmo intensificador de imagens. Foram avaliados o tempo total da cirurgia (em minutos) e a emissão de raios X medida em centigrays. Resultados A fixação das fraturas transtrocanterianas com PFN proporciona um menor tempo cirúrgico com uma diferença estatística significativa (p =0,013), quando comparada com as demais técnicas utilizadas entre os grupos envolvidos. Foi observada, também, uma menor exposição intraoperatória aos raios X (p =0,015), a qual foi estatisticamente relevante quando utilizado o DHS como método de fixação comparado com o gama nail e o PFN. Conclusão Apesar do PFN ter o menor tempo de cirurgia, a técnica do DHS se mostrou com menores níveis de exposição dentro da amostra estudada.


Subject(s)
Radiology , Surgical Procedures, Operative , X-Rays , Internal Fixators , Femoral Fractures , Operative Time , Neoplasms
2.
Arq. bras. med. vet. zootec. (Online) ; 71(4): 1339-1347, jul.-ago. 2019. tab, graf, ilus
Article in Portuguese | VETINDEX, LILACS | ID: biblio-1038623

ABSTRACT

O presente estudo objetivou comparar, biomecanicamente, por meio do ensaio de compressão excêntrica, a resistência dos implantes Clamp and Rod Internal Fixation (CRIF) 5,0mm e placa de reconstrução 3,5mm na fixação de fraturas distais de fêmur de cão. Foram utilizados 22 fêmures de 11 cadáveres de cão entre 2 e 7 anos de idade e peso corporal entre 20 e 40kg e subdivididos em dois grupos, denominados grupo CRIF (GC - 11 fêmures) e grupo placa (GP - 11 fêmures). Para realização dos testes, foi simulada falha que mimetizasse uma fratura distal nos corpos de prova, por meio de uma osteotomia de até 0,5cm, realizada com auxílio de serra oscilatória, imediatamente proximal ao início da tróclea. Os implantes foram fixados segundo os padrões AOSIF, lateralmente ao fêmur, sendo utilizados três parafusos distais e cinco proximais ao foco de fratura. Foi empregado o programa de computador PMI para calcular o ponto máximo de resistência antes da falha e avaliaram-se as variáveis força máxima, deformação máxima real, rigidez, força intermediária e deformação intermediária real. Não foram encontradas diferenças estatisticamente significativas entre os GC e GP quanto às variáveis avaliadas, sugerindo que ambos os implantes são boas opções de fixações para tais fraturas.(AU)


This study aims to compare the biomechanical properties, through compression eccentric test, of the resistance of the 5.0mm Clamp and Rod Internal Fixation Implants (CRIF) and 3.5mm reconstruction plate in fixing dog femur distal fracture. It was used 22 femurs from 11 dog cadavers with age between 2 and 7 years old and body weight between 20 and 40kg, subdivided into two groups, called CRIF Group (CG - 11 femurs) and plate group (PG - 11 femurs). A distal fracture in the specimens with a gap of 0.5cm osteotomy, was simulated to perform the test, performed by the oscillating saw, just proximal to the beginning of the trochlea. The implants were fixed by the standards AO / SIF, laterally to the femur, using three distal screws and five proximal to the fracture site. PMI computer program was used to calculate the maximum point of resistance before failure and evaluated the variables maximum strength, real maximum deformation, stiffness, intermediate strength and real intermediate deformation. No statistically significant differences were found between the GC and GP as the variables evaluated, suggesting that both implants are good fixation options for such fractures.(AU)


Subject(s)
Animals , Dogs , Bone Plates/veterinary , Internal Fixators/veterinary , Femoral Fractures/veterinary , Fracture Fixation/methods , Fracture Fixation/veterinary
3.
Rev. Assoc. Med. Bras. (1992) ; 65(2): 198-203, Feb. 2019. tab, graf
Article in English | LILACS | ID: biblio-990341

ABSTRACT

SUMMARY OBJECTIVE: To present the surgical results of patients who underwent axis screw instrumentation, discussing surgical nuances and complications of the techniques used. METHODS: Retrospective case-series evaluation of patients who underwent spinal surgery with axis instrumentation using screws. RESULTS: Sixty-five patients were included in this study. The most common cause of mechanical instability was spinal cord trauma involving the axis (36 patients - 55.4%), followed by congenital craniocervical malformation (12 patients - 18.5%). Thirty-seven (57%) patients required concomitant C1 fusion. Bilateral axis fixation was performed in almost all cases. Twenty-three patients (35.4%) underwent bilateral laminar screws fixation; pars screws were used in twenty-two patients (33.8%), and pedicular screws were used isolated in only three patients (4.6%). In fourteen patients (21.5%), we performed a hybrid construction. There was no neurological worsening nor vertebral artery injury in this series. CONCLUSION: Axis screw instrumentation proved to be a safe and efficient method for cervical stabilization. Laminar and pars screws were the most commonly used


RESUMO OBJETIVO: Apresentar os resultados cirúrgicos de pacientes submetidos à instrumentação com parafusos do áxis, discutindo nuances cirúrgicas e complicações das técnicas utilizadas. MÉTODOS: Série retrospectiva de pacientes submetidos à instrumentação do áxis utilizando parafusos. RESULTADOS: Sessenta e cinco pacientes foram incluídos neste estudo. A causa mais comum de instabilidade foi trauma raquimedular envolvendo o áxis (36 pacientes - 55,4%), seguida por malformação craniocervical congênita (12 pacientes - 18,5%). Trinta e sete (57%) pacientes necessitaram concomitante fusão de C1. Fixação bilateral foi realizada em quase todos os casos. Vinte e três pacientes (35,4%) foram submetidos à fixação com parafusos de lâmina; parafusos de pars foram utilizados em 22 pacientes (33,8%) e de pedículo, isoladamente, em três (4,6%). Em 14 casos (21,5%), realizamos técnicas combinadas. Não houve piora neurológica ou lesão de artéria vertebral nesta série de casos. CONCLUSÃO: A instrumentação com parafusos do áxis foi um método seguro e eficaz para estabilização cervical. A fixação da lâmina e a da pars foram as técnicas mais utilizadas.


Subject(s)
Humans , Male , Female , Child, Preschool , Child , Adolescent , Adult , Aged , Young Adult , Spinal Fusion/instrumentation , Axis, Cervical Vertebra/surgery , Bone Screws/adverse effects , Postoperative Complications , Spinal Fusion/adverse effects , Spinal Fusion/methods , Retrospective Studies , Treatment Outcome , Middle Aged
4.
Coluna/Columna ; 15(1): 22-25, Jan.-Mar. 2016. tab, graf
Article in English | LILACS | ID: lil-779075

ABSTRACT

ABSTRACT Objectives: To compare the outcomes of surgical treatment with lumbar fixation using nitinol rods without fusion and with standard lumbar fixation with titanium rods and interbody fusion. Methods: Treatment results of 70 patients with degenerative lumbar scoliosis aged 40 to 82 were analyzed. In all cases pedicle screws and nitinol rods with a diameter of 5.5 mm were used. Thirty patients underwent fixation at L1-S1 and 40 patients underwent fixation at L1-L5. Spinal fusion was not performed. All patients had radiography, CT and MRI performed. The results were assessed according to the Oswestry scale, SRS 22, SF 36 and VAS. The minimum follow-up period for all patients was 2.5 years. For the control group, consisting of 72 patients, pedicle fixation with titanium rods and interbody fusion in the lumbosacral region were performed. Results: The average level of deformity correction equaled 25° (10° - 38°). The analysis of X-ray and CT-scans revealed a single patient with implant instability, two patients with bone resorption around the screws and one patient with rod fractures. Functional radiography 2.5 years after surgery showed an average mobility of the lumbar spine of 21° (15° - 30°). There were no problems at the adjacent levels. Conclusions: The use of nitinol rods in spinal deformity surgery is promising. This technology is an alternative to rigid fixation. Continued gathering of clinical data and its further evaluation is necessary.


RESUMO Objetivos: Comparar os resultados de tratamento cirúrgico com fixação lombar usando hastes de nitinol sem artrodese e com fixação lombar padrão com hastes de titânio e fusão intersomática. Métodos: Foram analisados os resultados do tratamento em 70 pacientes com escoliose lombar degenerativa com idades entre 40 e 82 anos. Em todos os casos, foram usados parafusos pediculares e hastes de nitinol com diâmetro de 5,5 mm. Trinta pacientes foram submetidos à fixação em L1-S1 e 40 pacientes tiveram fixação em L1-L5. Não foi realizada artrodese da coluna. Todos os pacientes fizeram radiografias, TC e RM. Os resultados foram avaliados de acordo com a escala de Oswestry, com o SRS 22, o SF 36 e EVA. O período mínimo de acompanhamento para todos os pacientes foi de 2,5 anos. No grupo controle, com 72 pacientes, realizou-se a fixação do pedículo com hastes de titânio e fusão intersomática na região lombossacral. Resultados: O nível médio de correção da deformidade correspondeu a 25° (10°-38°). A análise das radiografias e das TC revelou um único paciente com instabilidade, dois pacientes com reabsorção óssea ao redor dos parafusos e um paciente apresentou fraturas da haste. A radiografia funcional 2,5 anos após a cirurgia mostrou mobilidade média da coluna lombar de 21° (15°-30°). Não foram encontrados problemas nos níveis adjacentes. Conclusões: O uso de hastes de nitinol na cirurgia de deformidades da coluna é promissor. Essa tecnologia é uma alternativa à fixação rígida. É preciso manter a coleta continuada de dados clínicos e sua posterior avaliação.


RESUMEN Objetivos: Comparar los resultados de tratamiento quirúrgico con fijación lumbar usando varillas de nitinol sin artrodesis y con fijación lumbar estándar con varillas de titanio y fusión intersomática. Métodos: Fueron analizados los resultados del tratamiento en 70 pacientes con escoliosis lumbar degenerativa con edades entre 40 y 82 años. En todos los casos, fueron usados tornillos pediculares y varillas de nitinol con diámetro de 5,5 mm. Treinta pacientes fueron sometidos a fijación en L1-S1 y 40 pacientes tuvieron fijación en L1-L5. No fue realizada artrodesis de la columna. Todos los pacientes hicieron radiografías, TC y RM. Los resultados fueron evaluados de acuerdo con la escala de Oswestry, con SRS 22, SF 36 y EVA. El período mínimo de acompañamiento para todos los pacientes fue de 2,5 años. En el grupo control, con 72 pacientes, se realizó la fijación del pedículo con varillas de titanio y fusión intersomática en la región lumbosacra. Resultados: El nivel medio de corrección de la deformidad correspondió a 25° (10°-38°). El análisis de las radiografías y de las TC reveló un único paciente con inestabilidad, dos pacientes con reabsorción ósea alrededor de los tornillos y un paciente presentó fracturas de la varilla. La radiografía funcional 2,5 años después de la cirugía mostró movilidad media de la columna lumbar de 21° (15°-30°). No fueron encontrados problemas en los niveles adyacentes. Conclusiones: El uso de varillas de nitinol en la cirugía de deformidades de la columna es promisor. Esa tecnología es una alternativa para la fijación rígida. Es preciso mantener la colecta continuada de datos clínicos y su posterior evaluación.


Subject(s)
Humans , Scoliosis/surgery , Orthopedic Fixation Devices , Internal Fixators , Pedicle Screws
5.
Rev. bras. ortop ; 49(6): 586-592, Nov-Dec/2014. tab, graf
Article in English | LILACS | ID: lil-732895

ABSTRACT

Objective: To statistically analyze the results obtained from biomechanical tests on fixation of femoral neck fractures of Pauwels III type, in synthetic bone, using the dynamic hip system with an anti-rotation screw, versus a control group. Methods: Ten synthetic bones from a Brazilian manufacturer (model C1010) were used and divided into two groups: test and control. In the test group, fixation of an osteotomy was performed with 70° of inclination at the level of the femoral neck, using DHS with an anti-rotation screw. The resistance of this fixation was evaluated, along with its rotational deviation at 5 mm of displacement (phase 1) and at 10 mm of displacement (phase 2), which was considered to be failure of synthesis. In the control group, the models were tested in their entirety until femoral neck fracturing occurred. Results: The test values in the test group (samples 1-5) in phase 1 were: 1512N, 1439 N, 1205 N, 1251N and 1273 N, respectively (mean = 1336 N; standard deviation SD] = 132 N). The rotational deviations were: 4.90°, 3.27°, 2.62°, 0.66° and 0.66°, respectively (mean = 2.42°; SD = 1.81°). In phase 2, we obtained: 2064 N, 1895 N, 1682 N, 1713 N and 1354 N, respectively (mean = 1742 N; SD = 265N). The failure loading values in the control group were: 1544 N, 1110 N, 1359 N, 1194 N and 1437 N, respectively (mean = 1329 N; SD = 177N). The statistical analysis using the Mann-Whitney test showed that the test group presented maximum loading at a displacement of 10 mm, i.e. significantly greater than the failure loading of the control group (p = 0.047). Conclusion: The mechanical resistance of the test group was significantly greater than that of the control group...


Objetivo: Analisar estatisticamente resultados obtidos em ensaios biomecânicos de fixação de fratura do colo femoral tipo Pauwels III, em osso sintético, com o uso do sistema dinâmico do quadril (DHS) com parafuso antirrotatório vs um grupo controle. Métodos: Foram usados dez ossos sintéticos, de um fabricante nacional, do modelo C1010, divididos em dois grupos: teste e controle. No grupo teste foi feita fixação de osteotomia, com 70° de inclinação em nível de colo femoral, com o uso de DHS com parafuso antirrotatório. Avaliou-se a resistência dessa fixação e seu desvio rotacional em 5 mm de deslocamento (fase 1) e em 10 mm de deslocamento, considerado como falência da síntese (fase 2). No grupo controle, os modelos foram ensaiados em sua integridade até que ocorresse a fratura do colo femoral. Resultados: Os valores do ensaio no grupo teste na fase 1, nas amostras de 1 a 5, foram: 1.512 N, 1.439 N, 1.205 N, 1.251 N e 1.273 N, respectivamente (média = 1.336 N; desvio padrão DP] = 132 N). Os desvios rotacionais foram: 4,90°; 3,27°; 2,62°; 0,66° e 0,66°, respectivamente (média = 2,42°; DP = 1,81°). Na fase 2, obtivemos: 2.064N, 1.895 N, 1.682N, 1.713 N e 1.354N, respectivamente (média = 1.742 N; DP = 265 N). Os valores da carga de falência no grupo controle foram: 1.544N, 1.110N, 1.359N, 1.194N e 1.437N, respectivamente (média = 1.329N; DP = 177 N). A análise estatística pelo teste de Mann-Whitney demonstrou que o grupo teste apresentou carga máxima, em 10 mm de deslocamento, significativamente maior do que a carga de falência do grupo controle (p = 0,047). Conclusão: A resistência mecânica do grupo teste foi significativamente superior à do grupo controle...


Subject(s)
Humans , Femoral Neck Fractures , Internal Fixators
6.
Acta ortop. bras ; 22(6): 315-320, Nov-Dec/2014. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-779399

ABSTRACT

O objetivo deste estudo prospectivo foi testar se o tratamentode lesões de Lisfranc com redução aberta e fixação da placadorsal teria os mesmos resultados funcionais, ou melhores, do quetratamento padrão com fixação com parafuso transarticular. Métodos:Sessenta pacientes com lesão articular de Lisfranc foram tratadospor redução aberta e fixação da placa dorsal ou pelo método padrãopor fixação de parafusos. Os pacientes foram acompanhados por,em média, 31 meses. A avaliação foi realizada com base na queixaprincipal dos pacientes, exame clínico, radiografia, e escala AOFAS.Resultados: Trinta e dois pacientes foram tratados com redução abertae fixação da placa dorsal, e vinte e oito pacientes foram tratadoscom redução aberta e fixação com parafuso. Depois de dois anos deacompanhamento, a média do escore AOFAS foi de 83,1 pontos nogrupo de fixação da placa dorsal e 78,5 pontos no grupo de fixaçãocom parafusos (p <0,01). Do grupo de fixação com placa dorsal, aanálise radiográfica revelou redução anatômica em vinte e nove pacientes(90,6%, 29/32) e redução não anatômica em três pacientes.Do grupo de fixação com parafuso, a análise radiográfica revelou reduçãoanatômica em vinte e três pacientes e redução não anatômicaem cinco pacientes (82,1%, 23/28). Conclusões: A redução abertae fixação com placa dorsal para lesão de Lisfranc deslocada têmmelhor resultado a curto e médio prazo e uma taxa de reoperaçãoinferior do que a técnica padrão de redução aberta e fixação interna(RAFI) com parafuso. Em nossa experiência, recomendamos o usode placa dorsal em RAFI nas lesões de Lisfranc deslocadas. Nívelde Evidência II, Estudo Prospectivo Comparativo...


The objective of this prospective study was to testwhether the treatment of Lisfranc injuries with open reductionand dorsal plate fixation would have the same or better functionaloutcomes as treatment with standard trans-articular screwfixation. Methods: Sixty patients with primarily isolated Lisfrancjoint injury were treated by open reduction and dorsal platefixation or standard screw fixation. The patients were followedon average for 31 months. Evaluation was performed with patients’chief complaint, clinical examination, radiography, andAOFAS Midfoot Scale. Results: Thirty two patients were treatedwith open reduction and dorsal plate fixation, and twenty eightpatients were treated with open reduction and screw fixation.After two years follow-up, the mean AOFAS Midfoot score was83.1 points in the dorsal plate fixation group and 78.5 points inthe screw fixation group (p<0.01). Of the dorsal plate fixationgroup, radiographic analysis revealed anatomic reduction intwenty-nine patients (90.6%, 29/32) and nonanatomic reductionin three patients. Of the screw fixation group, radiographicanalysis revealed anatomic reduction in twenty-three patientsand nonanatomic reduction in five patients (82.1%, 23/28).Conclusions: Open reduction and dorsal plate fixation for adislocated Lisfranc injury do have better short and median termoutcome and a lower reoperation rate than standard screw ORIF.In our experience, we recommend using dorsal plate in ORIF ondislocated Lisfranc injuries. Level of Evidence II, ProspectiveComparative Study...


Subject(s)
Humans , Male , Female , Tarsal Joints , Joints/injuries , Arthrodesis , Prospective Studies , Internal Fixators , Bone Screws
7.
Acta ortop. bras ; 22(5): 264-268, Sep-Oct/2014. ilus, tab, graf
Article in English, Portuguese | LILACS | ID: lil-783280

ABSTRACT

Analisar estatisticamente resultados obtidos em ensaiosbiomecânicos da fixação de fratura do colo do fêmur Pauwelstipo III, em osso sintético, com parafuso dinâmico condilar (DCS) egrupo controle. Método: Foram utilizados dez ossos sintéticos defabricação nacional. Grupo teste: foi realizada fixação após osteotomiaa 70o de inclinação, utilizando placa DCS de quatro furos.Analisou-se a resistência desta fixação em 5 mm de deslocamentoe desvio rotacional (Fase 1), e a 10 mm (Fase 2). Grupo controle: osmodelos foram ensaiados em sua integridade até que ocorresse afratura do colo femoral. Resultados: Os valores do ensaio no grupoteste na fase 1 apresentaram média de 974N e DP= 114N. Na fase2, obtiveram média de 1335N e DP=98N. Os valores da carga nogrupo controle foram: 1544N, 1110N, 1359N, 1194N, 1437N, respectivamente.A análise estatística pelo teste de Mann-Whitney paracomparação da força máxima (N) entre o grupo teste e o controle,na fase 2, demostrou que não existe diferença significativa entre asplacas DCS e controle (p = 0,91). Conclusão: Não existe diferençasignificativa entre as placas DCS e o grupo controle submetido aforça máxima. Nível de Evidência III, Caso Controle...


To analyze statistically results in biomechanical testingof fixation of femoral neck Pauwels type III fractures, on syntheticbone, with dynamic condylar screw (DCS) and control group.Methods: Ten synthetic bones of a national brand were used. TestGroup: fixation was performed after osteotomy at 70o tilt usingDCS plate with four holes. We analyzed the resistance of thisfixation with 5 mm displacement and rotational deviation (Step 1)and with10 mm (Step 2). Control group: the models were testedin their integrity until the femoral neck fracture occurred. Results:The values of the test group in Step 1 showed a mean of 974Nand SD = 114N. In Stage 2, we obtained on average 1335N andSD = 98N. The values in the control group were: 1544N, 1110N,1359N, 1194N, 1437N, respectively. Statistical analysis using theMann-Whitney test for comparison of the maximum force (N) betweenthe test group and the control, in Step 2, demonstrated thatthere is no significant difference between the DCS and controlplates (p = 0.91). Conclusion: There is no significant differencebetween the DCS boards and the control group exposed to fullresistance. Level of Evidence III, Case Control...


Subject(s)
Biomechanical Phenomena , Internal Fixators , Fracture Fixation , Femoral Neck Fractures , Bone and Bones , Osteotomy , Bone Screws
8.
Arq. bras. neurocir ; 33(2)jun. 2014. ilus, tab
Article in Portuguese | LILACS | ID: lil-721665

ABSTRACT

Objetivo: Avaliar a migração do espaçador intersomático (cage) em pacientes submetidos à artrodese lombar pela técnica transforaminal (TLIF). Método: Estudo retrospectivo de 27 pacientes submetidos à técnica TLIF nos níveis L4-L5, L5-S1 ou L4-L5 e L5-S1 para tratamento de patologia degenerativa da coluna lombar entre julho de 2009 e julho de 2011. Os dados referentes à migração do cage foram obtidos a partir da análise de imagens radiográficas da coluna lombar nas incidências anteroposterior (AP) e perfil nos momentos pré e pós-operatório com 1, 6 e 12 meses. O valor utilizado como critério de migração do cage foi determinado pelo deslocamento anterior ou posterior maior ou igual a 2 mm quando comparado a exame radiográfico pré e pós-operatório. Resultados: Foi inserido um total de 36 cages. Dos 27 pacientes avaliados, 15 (55,5%) apresentavam algum tipo de migração do cage - em 4 (14,8%) a migração foi para anterior e em 11 (40,7%) a migração foi para posterior. Conclusão:Encontramos migração em 55,5% do total de pacientes, e em 40,7% a migração foi posterior, porém sem necessidade de novas intervenções cirúrgicas.


Objective: To evaluate the cage migration in transforaminal lumbar interbody fusion (TLIF). Method: We retrospectively reviewed the records of 27 patients who had been diagnosed with degenerative lumbar disease, and who had undergone a transforaminal lumbar interbody fusion at L4-L5, L5-S1, and L4-L5/L5-S1 between July 2009 and July 2011. All data regarding the cage migration was obtained from preoperative and postoperative radiographs including standing anteroposterior (AP) and lateral. Clinical and radiographic assessment was performed at 1, 6 and 12 months after surgery. Cage migration was identified if cage moved posteriorly 2 mm or more compared with previous radiographs. Results: 36 cages were inserted. Cage migration was found in 15 of 27 patients (55,5%). Four cases of anterior displacement (14,8%) and 11 cases of posterior displacement (40,7%) were found. Conclusion: The rate of cage migration was 55.5%. In addition, 40.7% of posterior displacement was found but without further surgical intervention.


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Spinal Fusion/instrumentation , Spinal Fusion/methods , Internal Fixators , Postoperative Complications
9.
Coluna/Columna ; 12(2): 119-123, 2013. ilus, tab
Article in Spanish | LILACS | ID: lil-680726

ABSTRACT

OBJETIVO: Evaluar a un año el resultado del uso de espaciadores dinámicos en listésis grado I de Meyerding utilizando la escala de incapacidad de Oswestry. MÉTODOS: Se revisa el historial electrónico y radiográfico de los pacientes según criterios en el período de enero 2008 a diciembre 2010, con el propósito de realizar un estudio de cohortes, retrospectivo, longitudinal y observacional. RESULTADOS: El Oswestry prequirúrgico fue de 3.4% leve, 55.2% moderado y 41.4% severo; mientras que el posquirúrgico fue de 79.3% leve y 20.7% moderado. La cirugía realizada más común fue exploración y liberación con un 72.4%, presentando discectomía únicamente el 27.6%. Los pacientes presentaron dolor irradiado a miembro pélvico derecho en el 37.9%, miembro pélvico izquierdo 44.8% y a ambos miembros pélvicos en un 17.2%. Se presentó dolor posquirúrgico irradiado a miembro pélvico únicamente en el 2.4% siendo que el 100% de los casos presentaron algún tipo de dolor irradiado. Se utilizó espaciador DIAM en 79.3% y Wallis en 20.7% CONCLUSIONES: El tratamiento con espaciador interespinoso presenta un bajo índice de reintervención y por lo menos a un año presenta mejoría significativa en el índice de incapacidad.


OBJETIVO: Avaliar o resultado em ano do uso de espaçadores dinâmicos em listese de grau I de Meyerding, utilizando a escala de incapacidade de Oswestry. MÉTODOS: Foi revisado o prontuário eletrônico e as radiografias dos pacientes, de acordo com os critérios, no período de janeiro de 2008 a dezembro de 2010, visando realizar um estudo de coortes, retrospectivo, longitudinal e observacional. RESULTADOS: O índice de Oswestry pré-cirúrgico foi de 3,4% leves, 55,2% moderados e 41,4% graves, enquanto o pós-cirúrgico foi de 79,3% leves e 20,7% moderados. A cirurgia mais realizada foi exploração e liberação, em 72,4%, sendo que 27,6% apresentaram apenas discectomia. Os pacientes tinham dor irradiada para o membro inferior direito em 37.9%, para o membro inferior esquerdo em 44,8% e para ambos os membros inferiores, em 17,2%. Verificou-se dor pós-operatória irradiada para o membro inferior só em 2,4%, sendo que 100% dos casos tinham algum tipo de dor irradiada. Foi empregado o espaçador DIAM em 79.3% e o Wallis em 20.7% CONCLUSÕES: O tratamento com espaçador interespinhoso apresenta baixo índice de re-intervenção e pelo menos em um ano, apresenta melhora significante do índice de incapacidade.


OBJECTIVE: To evaluate one-year results of using dynamic spacers in listhesis grade I of Meyerding using Oswestry Disability Index. METHODS: The disability scale review was based in the electronic and radiographic history of patients according to criteria in the period from January 2008 to December 2010, in order to conduct a cohort study, retrospective, longitudinal, and observational. RESULTS: The Oswestry index before surgery was 3.4% mild, 55.2% moderate and severe 41.4%, while the postoperative was 79.3% mild and 20.7% moderate. The most common surgery performed was exploration and release in 72.4%, and only 27.6% had discectomy. Patients had pain radiating to right lower limb in 37.9%, to the left lower limb in 44.8% and to both lower extremities in 17.2%. Pain radiating to the lower limb after surgery was found only in 2.4%, and 100% of the cases had some type of radiating pain. The DIAM interspinous implant was used in 79.3%, and the Wallis in 20.7%. CONCLUSIONS: Treatment with interspinous spacer has a low rate of reoperation and at least during one year presented significant improvement in the rate of disability.


Subject(s)
Humans , Internal Fixators , Spine/surgery , Spondylolisthesis , Low Back Pain
10.
Rev. bras. ortop ; 47(5): 575-580, set.-out. 2012. tab
Article in Portuguese | LILACS | ID: lil-660906

ABSTRACT

OBJETIVO: Avaliar as indicações, epidemiologia, lesões associadas, complicações e prognóstico das fraturas diafisárias instáveis do fêmur na criança tratadas com hastes intramedulares elásticas de titânio. MÉTODO: Estudo retrospectivo composto por 24 pacientes com fraturas diafisárias instáveis do fêmur com idade entre cinco e 12 anos, submetidos a tratamento cirúrgico com hastes intramedulares elásticas de titânio no Hospital Universitário Cajuru - Curitiba, PR. Pacientes atendidos no período de abril de 2002 a março de 2008, com seguimento mínimo de 36 meses, submetidos à avaliação de dados epidemiológicos, desvios angulares, encurtamento e consolidação óssea. RESULTADOS: Foram reavaliados os prontuários de 113 casos operados de abril de 2002 a março de 2008, destes, incluídos no estudo 24 casos com fraturas de fêmur diafisárias instáveis tratadas com hastes intramedulares elásticas de titânio com inserção retrógrada. Apresentando duas fraturas bilaterais, duas fraturas expostas, sete pacientes do sexo feminino e 17 masculinos, com idade média de 8,3 anos. Apresentaram, ao final do estudo: encurtamento, desvios em varo ou valgo, retrocurvato ou antecurvato final igual a zero, não havendo ainda presença de retardo de consolidação ou pseudartrose. CONCLUSÕES: As hastes intramedulares elásticas de titânio são de fácil colocação e remoção. Consideramos a utilização das hastes intramedulares elásticas de titânio uma boa opção para a fixação de fraturas instáveis do fêmur em crianças.


OBJECTIVE: To evaluate the indications, epidemiology, associated lesions, complications and prognosis among children with unstable femoral diaphysis fractures who were treated with titanium elastic intramedullary nails. METHOD: This was a retrospective analysis on 24 patients aged 5-12 years with unstable femoral diaphysis fractures who underwent surgical treatment with elastic titanium intramedullary nails at the Cajuru University Hospital, Curitiba-PR between April 2002 and March 2008, with a minimum follow-up of 36 months. The epidemiological data, angular deviations, leg shortening and bone consolidation were evaluated. RESULTS: The medical files of 113 cases operated between April 2002 and March 2008 were reassessed. From these, 24 cases of unstable femoral diaphysis fractures treated with elastic titanium intramedullary nails with retrograde insertion were included in the study. There were two bilateral fractures and two exposed fractures. Seven patients were female and 17 were male, and the mean age was 8.3 years. The following were presented at the end of the study: shortening, varus or valgus displacement, final retrocurvatum or antecurvatum of zero, and absence of delayed consolidation or pseudarthrosis. CONCLUSIONS: The elastic titanium intramedullary nails were easily placed and removed. We believe that using elastic titanium intramedullary nails is a good option for fixation of unstable femoral fractures in children.


Subject(s)
Humans , Male , Female , Child , Fracture Fixation , Fracture Fixation, Intramedullary , Femoral Fractures/complications , Internal Fixators , Orthopedic Fixation Devices , Titanium
11.
Coluna/Columna ; 11(3): 195-199, July-Sept. 2012. ilus
Article in English | LILACS | ID: lil-654879

ABSTRACT

OBJECTIVE: The aim was to determine in vivo whether pre-operative mobility of the lumbar spine (overall and segmental) is retained after surgical intervention. METHODS: Functional imaging of the lumbar spine was performed in flexion and extension, using a lateral projection under standardised conditions. This allowed assessment of the overall mobility, mobility of the instrumented mobile segments and the disc height of the adjacent cranial segment (intervertebral space; IVS) before and after surgical intervention. Images were evaluated independently by a radiologist and an orthopaedic surgeon. A comparative analysis of preoperative and postoperative functional images was carried out with the aid of a computer and appropriate software (ACES) for further assessment of the extent to which the range of movement was retained. The Oswestry Disability Index (ODI, quality of life assessment) and the visual analogue scale (VAS, pain assessment) were used as clinical criteria and compared pre-and postoperatively. The mean follow-up (FU) intervals were 13.5 days (FU 1) and 19 months (FU 2). RESULTS: Radiological results showed that the overall mobility of the lumbar spine (L1 to S1) decreased on average by one third of the flexion/extension range, from 25.0º preoperatively to 17.6º postoperatively. The segmental mobility of the monosegmental stabilisation decreased on average from 3.7º to 2.3º. The caudal segments of the bisegmental dynamic stabilisation retained their preoperative movement range of 2.6º, with a postoperative range of 2.4º. The IVS did not change. The ODI improved postoperatively from 59 (preoperative) to 39/41 (FU1/FU2) points, while the VAS (during movement) improved from 7.6 (pre-op) to 4.4/4.5 (FU1/FU2). Computer-assisted analysis showed that small and functionally insignificant micro-motion of 0.4º (error 0.12%) remained in the stabilised and unfused mobile segment. CONCLUSION: Comparison of preoperative and postoperative measurements showed that overall mobility and segmental micro-motion were retained after non-fusion stabilisation of the lumbar spine with monosegmental and bisegmental instrumentation. The adjacent cranial segment (IVS) did not collapse. Activity levels (ODI) and pain symptoms (VAS) of the patients showed significant improvement at follow-up, comparable to that reported in the literature for conventional rigid spinal fusions.


OBJETIVO: O objetivo foi determinar in vivo se a mobilidade pré-operatória da coluna lombar (geral e segmentar) é mantida depois da intervenção cirúrgica. MÉTODOS: Foram realizadas imagens funcionais da coluna lombar em flexão e extensão, usando projeção lateral em condições padronizadas. Isso permitiu a avaliação da mobilidade geral, da mobilidade dos segmentos móveis instrumentados e da altura do disco do segmento rostral adjacente (espaço intervertebral; IVS) antes e depois da intervenção cirúrgica. As imagens foram analisadas independentemente por um radiologista e por um cirurgião ortopedista. Realizou-se análise comparativa das imagens funcionais pré e pós-operatórias com o auxílio de computador e de software apropriado (ACES) para avaliar mais detalhadamente a extensão em que a amplitude de movimento foi mantida. O Oswestry Disability Index (ODI, avaliação da qualidade de vida) e a escala visual analógica (VAS, avaliação da dor) foram usadas como critérios clínicos e comparadas no pré e pós-operatório. Os intervalos médios de acompanhamento (FU, de follow-up) foram 13,5 dias (FU 1) e 19 meses (FU 2). RESULTADOS: Os resultados radiológicos mostraram que a mobilidade geral da coluna lombar (L1 a S1) diminuiu, em média, um terço na amplitude de flexão e extensão, de 25,0º antes da cirurgia, para 17,6º depois. A mobilidade dos segmentos na estabilização monossegmentar diminuiu, em média, de 3,7º para 2,3º. Os segmentos caudais da estabilização dinâmica bissegmentar mantiveram a amplitude de movimento pré-cirúrgica de 2,6º, chegando até 2,4º depois da cirurgia. O IVS não foi alterado. O ODI melhorou depois da intervenção, de 59 para 39/41 (FU 1/FU 2) pontos, enquanto a VAS (durante movimento) melhorou de 7,6 (pré-operatório) para 4,4/4,5 (FU 1/FU 2). A análise auxiliada por computador mostrou que o pequeno e funcionalmente insignificante micromovimento de 0,4º (erro de 0,12%) permaneceu no segmento móvel estabilizado com técnica de não-fusão. CONCLUSÃO: A comparação das mensurações pré e pós-operatórias mostrou que a mobilidade geral e o micromovimento segmentar foram mantidos depois de estabilização da coluna lombar com técnica de não-fusão, com instrumentação mono e bissegmentar. O segmento rostral adjacente (IVS) não sofreu colapso. Os níveis de atividade (ODI) e os sintomas dolorosos (VAS) dos pacientes apresentaram melhora significante no acompanhamento, comparável aos relatados na literatura referentes às fusões espinais rígidas convencionais.


OBJETIVO: Fue determinar in vivo si la movilidad preoperatoria de la espina lumbar (general y segmentaria) se mantiene después de la intervención quirúrgica. MÉTODOS: La representación por imágenes de la espina lumbar se realizó en flexión y extensión, usándose una proyección lateral en condiciones estandarizadas. Esto permitió la evaluación de la movilidad general, la movilidad de los segmentos móviles instrumentados y la altura de disco del segmento craneano adyacente (espacio intervertebral; IVS), antes y después de la intervención quirúrgica. Las imágenes fueron evaluadas, independientemente, por un radiólogo y un cirujano ortopedista. Un análisis comparativo de las imágenes funcionales preoperatorias y posoperatorias fue realizado con la ayuda de una computadora y del software apropiado (ACES) para evaluación adicional de la extensión hasta la cual se mantuvo la amplitud del movimiento. El Índice de Incapacidad de Oswestry (ODI, evaluación de la calidad de vida) y la escala análoga visual (VAS, evaluación del dolor) fueron usados como criterios clínicos y comparados antes y después de la cirugía. Los intervalos promedio de seguimiento (FU) fueron 13,5 días (FU 1) y 19 meses (FU 2). RESULTADOS: Los resultados radiológicos muestran que la movilidad general de la espina lumbar (L1 a S1) se redujo, en promedio, en un tercio de la amplitud de flexión/extensión, de 25,0º antes de la cirugía a 17,6º después de la cirugía. La movilidad segmentaria, de la estabilización monosegmentaria, disminuyó, en promedio, de 3,7º a 2,3º. Los segmentos caudales de la estabilización dinámica bisegmentaria mantuvieron su amplitud de movimiento preoperatorio de 2,6º, con una extensión de 2,4º después de la cirugía. El IVS no cambió. El ODI mejoró después de la cirugía de 59 (preoperatorio) puntos a 39/41 (FU1/FU2), mientras que la VAS (durante el movimiento) mejoró de 7,6 (preoperatoria) a 4,4/4,5 (FU1/FU2). El análisis, con ayuda de la computadora, mostró que un pequeño micromovimiento, funcionalmente insignificante, de 0,4º (error 0,12%) permaneció en el segmento móvil estabilizado y no fusionado. CONCLUSIÓN: La comparación de las mediciones preoperatoria y posoperatoria mostró que la movilidad general y el micromovimiento segmentario fueron mantenidos después de la estabilización no fusionada de la espina lumbar con instrumentación monosegmentaria y bisegmentaria. El segmento craneano adyacente (IVS) no tuvo un colapso. Los niveles de actividad (ODI) y los síntomas de dolor (VAS) de los pacientes mostraron mejoría significativa en el seguimiento, comparable a la que se informa en la literatura para fusiones espinales convencionales, rígidas.


Subject(s)
Humans , Bone Screws , Spine , Radiography , Lumbosacral Region
12.
Coluna/Columna ; 11(1): 24-28, 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-623154

ABSTRACT

OBJETIVO: Avaliação da evolução radiográfica da lesão da coluna vertebral cervical tratada pela fixação posterior isolada. MÉTODOS: De 2000 a 2008 foram selecionados 23 pacientes que atenderam aos critérios de inclusão do estudo. Eram masculinos 91,3% e a idade média foi de 34 anos e quatro meses. O tempo de seguimento médio foi de 82 meses. Foi avaliado no exame de imagem pré-operatório, pós-operatório imediato e após seis meses de evolução o tipo de implante, a consolidação da artrodese, se houve soltura do implante, perda de redução, cifose segmentar, degeneração de nível adjacente e pseudartrose. RESULTADOS: Em relação ao método de síntese, 60,8% dos pacientes foram submetidos ao amarrilho interespinhoso, 26% à placa com parafusos de massa lateral e 13% à barra com parafusos de massa lateral. Dos pacientes submetidos à fixação com parafusos, nenhum apresentou complicações radiográficas e 35,7% dos pacientes submetidos à artrodese com amarrilho interespinhoso tiveram complicação, sendo a mais frequente a cifose segmentar. CONCLUSÃO: As lesões da coluna cervical submetidas a artrodese com parafuso de massa lateral apresentaram uma evolução radiográfica melhor do que as submetidas a fixação com amarrilho interespinhoso, tendo este último apresentado maior incidência de complicações na artrodese.


OBJECTIVE: To perform a radiographic evaluation of the cervical spine injury treated with posterior fixation techniques only. METHODS: From 2000 to 2008, twenty three patients were included in the study, of which 91,3% were men, with a mean age of thirty-four years and four months. The mean follow-up time was 82 months. The type of implant used, the radiographic arthrodesis consolidation, implant failure, lost of reduction, segmental kyphosis and pseudarthrosis were evaluatedin the preoperative period, the immediate postoperative period and after six months of evolution, based on the patients records. RESULTS: When it comes to the type of implant used, there were 60,8% of the patients who underwent interspinous wire fixation, 26% with lateral mass screws and plate and 13% with lateral mass screws and rods. Of the lateral mass screws patients, none had radiographic complications and 35,7% of the interspinous wire patients had complications being the segmental kyphosis the most frequent of them. CONCLUSIONS: The cervical spine injuries that underwent lateral mass screw fixation showed better radiographic results, with less complications than the interspinous wire fixation.


OBJETIVO: Evaluación de la evolución radiológica de la lesión de la columna cervical tratada con fijación posterior aislada. MÉTODOS: De 2000 a 2008, se seleccionaron 23 pacientes que cumplían los criterios de inclusión del estudio. 91,3% eran varones y la edad media fue de 34 años y cuatro meses. El período de seguimiento promedio fue 82 meses. Se evaluó, en los exámenes de imágenes antes de la cirugía, inmediatamente después de la operación y después de seis meses de evolución, el tipo de implante, la consolidación de la artrodesis, si había aflojamiento del implante, la pérdida de la reducción, la cifosis segmentaria, la degeneración de nivel adyacente y la pseudoartrosis. RESULTADOS: En comparación con el método de síntesis, 60,8% de los pacientes se sometieron a fijación por cableado interespinoso, 26% a la placa con tornillos de masa lateral y 13% a la barra con tornillos de masa lateral. De los pacientes sometidos a fijación con tornillos, ninguno presentó complicaciones radiográficas y 35,7% de los pacientes sometidos a la fusión con el cableado interespinoso presentaron complicaciones, siendo la cifosis segmentaria la más frecuente. CONCLUSIÓN: Las lesiones de columna cervical sometidas a la fusión con el tornillo de masa lateral presentaron una evolución radiográfica mejor que las de quienesfueron sometidos a fijación con cableado interespinoso, esta última presentó una mayor incidencia de complicaciones en la artrodesis.


Subject(s)
Cerclage, Cervical , Cervical Vertebrae , Fracture Fixation , Internal Fixators , Orthopedic Fixation Devices , Spinal Fractures , Spinal Injuries
13.
Acta fisiátrica ; 18(4): 163-168, dez. 2011.
Article in English, Portuguese | LILACS | ID: lil-663377

ABSTRACT

As fraturas do rádio distal estão entre as mais comuns do esqueleto humano, correspondendo a um sexto de todas as fraturas. Para seu tratamento, existem diversas técnicas cirúrgicas e materiais de síntese que podem ser utilizados, no entanto, o uso de placa volar tem se mostrado eficiente e apresentado poucas complicações. Objetivo: Realizar uma análise retrospectiva do estado funcional de pacientes com fratura do radio distal submetidos à osteossíntese com placa volar LCP que passaram por um programa de reabilitação. Método: A amostra foi composta por 14 pacientes com fratura unilateral de rádio distal submetidos à osteossíntese com placa volar LCP 2,4 mm ou 3,5 mm. Os indivíduos foram divididos em dois grupos: grupo acometido (n = 14), composto pelos punhos fraturados; grupo controle (n = 14) composto pelos punhos contralaterais. Foram realizadas medidas de amplitude de movimento (ADM) ativa e passiva do punho, força de preensão e pinças e aplicado um questionário de disfunção do membro superior (DASH). Para a análise dos dados, foi realizada comparação entre os grupos, acometido e controle, por meio de testes de significância de duas amostras independentes para médias. Resultados: A média encontrada para o questionário DASH foi de 10,63 pontos (± 12,23). Em relação às medidas de força de preensão e pinças, e de ADM de punho, não houve diferenças significantes na comparação entre os grupos (p > 0,05). Conclusão: Na amostra analisada, pode-se concluir que, após um ano de pós-operatório, os pacientes apresentam resultados semelhantes na comparação, o que evidencia uma recuperação satisfatória do estado funcional.


Distal radius fractures are the most common fractures of the human skeleton, accounting for one sixth of all fractures. For his treatment, there are several surgical techniques and synthesizing materials that can be used, however, the use of a volar plate has been proven effective and haspresented few complications. Objective: Here was to make a retrospective study of thefunctionality of patients with distal radius fracture after internal fixation with an LCP volar plate that went through a rehabilitation program. Method: The sample consisted of 14 patients with unilateral distal radius fracture who underwent internal fixation with a 2.4 mm or 3.5 mm LCP volar plate who completed 1 year after surgery in 2010. The subjects were divided into two groups: affected group (n = 14), composed of fractured wrists; control group (n = 14) composed of the contralateral wrists. Measurements were made of active and passive range of motion (ROM) of the wrist, grip strength, pinch grip strength, and a questionnaire of disabilities of the arm, shoulder, and hand (DASH). The data was analyzed to compare the affected and controlgroups, through tests of significance of two independent samples for means. Results: The average for the DASH questionnaire was 10.63 points (± 12.23). For measures of grip strength, pinch grip strength, and ROM, there were no significant differences in comparison groups (p > 0.05). Conclusion: We concluded that after one year post-surgery, patients showed similar results when comparing the wrists, which shows a satisfactory recovery of functional status.


Subject(s)
Humans , Male , Female , Internal Fixators , Fracture Fixation, Internal/rehabilitation , Radius Fractures/rehabilitation , Bone Plates , Retrospective Studies , Control Groups , Surveys and Questionnaires
14.
Acta ortop. bras ; 19(4): 210-212, 2011. ilus
Article in Portuguese | LILACS | ID: lil-601830

ABSTRACT

OBJETIVO: O cúbito varo é uma doença muito comum em crianças e adultos, ocasionada por fratura supracondilar. Existem vários procedimentos cirúrgicos e fixações internas para correção do cúbito varo, com diferentes desfechos, embora a fixação interna com placa e parafusos seja o mais comum. Contudo, o impacto do posicionamento da placa sobre a cirurgia raramente foi estudado até agora. MÉTODO: Em nosso estudo, 12 pacientes com cúbito varo foram divididos em dois grupos, operados pelo método de osteotomias em cunha com fechamento lateral e fixações internas com placa e parafusos. Em um grupo, as placas foram colocadas no lado póstero-lateral; no outro, as placas foram colocadas no lado lateral do úmero. RESULTADO: O período de acompanhamento foi 4,5 meses (faixa de 2 a 7 meses). Houve cinco resultados excelentes (83,3 por cento) e um bom (16,7 por cento) em cada grupo. Em todos os casos, a aparência é muito semelhante ao lado oposto; não há diferenças de amplitude de movimento (AM) no cotovelo depois da cirurgia. Um paciente no grupo B teve paralisia nervosa transitória; não houve infecções nem osteomielite. CONCLUSÃO: A posição da placa de fixação interna não tem impacto sobre a osteotomia em cunha de fechamento lateral. Nivel de Evidência II, Prospectivo Comparativo.


OBJECTIVE: To study the effects of low intensity ultrasound irradiation applied on the spinal cord, in the regeneration of the rat's sciatic nerve after a controlled crush injury, evaluating the functional results of the sciatic functional index as measured on video recorded images of the foot sole. METHODS: Eighteen rats were submitted to a controlled crush injury of the right sciatic nerve, and divided into two groups according to the treatment: Group 1 (n=9), simulated irradiation; Group 2 (n=9), effective irradiation. Low-intensity ultrasound irradiation was started on the 7th postoperative day and applied daily for 6 weeks. Images of the animals´ foot soles were video recorded on a transparenttreadmill belt at weekly intervals until the 6th week of irradiation, and the corresponding sciatic functional index (SFI) was measured usingspecific software. RESULTS: The SFI during the first and last week of treatment was -59.12 and -12.55 in Group 1, -53.31 and -1.32 in Group 2, indicating improvements of 79 percent and 97 percent, respectively, but differences between the groups were only significant (p<0.05) during the third week of treatment. CONCLUSION: The authors conclude that low intensity therapeutic ultrasound enhances nerve regeneration, with significance during the 3rd week of treatment. Level of Evidence: Level II, prospective comparative study.


Subject(s)
Humans , Male , Female , Child , Adolescent , Elbow/surgery , Elbow/injuries , Fracture Fixation, Internal/methods , Osteotomy/methods , Osteotomy/rehabilitation , Ulna Fractures , Bone Plates , Bone Screws , Elbow
15.
Coluna/Columna ; 9(2): 126-131, abr.-jun. 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-557031

ABSTRACT

Avaliar a correção da cifose, da altura do corpo vertebral e da redução dos fragmentos retropulsados nas fraturas toracolombares tipo explosão por ligamentotaxia. MÉTODOS: estudo retrospectivo avaliando um total de 238 pacientes com fraturas toracolombares tipo explosão do grupo A3 pela classificação de Magerl et al., dos quais 63 deles elegíveis para a pesquisa. Todos foram tratados com fixador interno pedicular e tinham imagens radiográficas e tomográficas pré e pós-operatórias. RESULTADOS: No estudo, foi constatada, no pós-operatório imediato, uma correção da cifose vertebral no local da fratura de 87 por cento, com correção de 51 por cento na altura do corpo vertebral e redução de 40 por cento dos fragmentos retropulsados intracanal. CONCLUSÕES: o uso de fixador interno por via posterior permite, ao realizar ligamentotaxia, a restauração da altura do corpo vertebral fraturado, do alinhamento sagital da coluna e descompressão do canal espinhal, minimizando as comorbidades em relação à cirurgia pela via anterior e à laminectomia para descompressão do canal.


To evaluate the correction of kyphosis, of the vertebral body height and the reduction of the retropulsed fragments in the thoracolumbar burst fractures by means of ligamentotaxis. METHODS: retrospective study evaluating a total of 238 patients with thoracolumbar A3 burst fractures based on the classification by Magerl et al., of which 63 were eligible to the research. All patients had been treated with pedicular internal fixation and had previous and postoperative radiographs and computed tomographic images. RESULTS: the study evidenced an immediate postoperative correction of vertebral kyphosis in the fracture site in 87 percent of the cases, with correction of 51 percent in the vertebral body height and reduction of 40 percent the intra-canal retropulsed fragments. CONCLUSIONS: the use of internal fixation by anterior approach allows, through ligamentotaxis, the restoration of the height of the vertebral body fracture, of the sagittal alignment of the column and spinal canal decompression, thus minimizing the comorbidities in relation to the surgery by anterior approach and laminectomy to canal decompression.


Evaluar la corrección de la cifosis, de la altura del cuerpo vertebral y de la reducción de los fragmentos retro pulsados en las fracturas toracolumbares tipo explosión por ligamentotaxia. MÉTODOS: estudio retrospectivo evaluando un total de 238 pacientes con fracturas toracolumbares tipo explosión del Grupo A3 por la clasificación de Magerl et al., de los cuales 63 de ellos fueron elegidos para la investigación. Todos fueron tratados con fijador interno pedicular y tenían imágenes radiográficas y de tomografías pre y postoperatorias. RESULTADOS: en el estudio, se constató en el postoperatorio inmediato una corrección de la cifosis vertebral en el local de la fractura de 87 por ciento con corrección de 51 por ciento en la altura del cuerpo vertebral, y una reducción de 40 por ciento de los fragmentos retro pulsados intracanal. CONCLUSIONES: el uso del fijador interno por vía posterior permite, al realizar ligamentotaxia, la restauración de la altura del cuerpo vertebral fracturado, del alineamiento sagital de la columna y descompresión del canal espinal minimizando la comorbidad en relación a la cirugía por vía anterior y la laminectomía para descompresión del canal.


Subject(s)
Kyphosis/surgery , Spinal Fractures/surgery , Internal Fixators , Longitudinal Ligaments , Spinal Canal
16.
Rev. bras. ortop ; 45(1): 67-71, 2010. ilus
Article in Portuguese | LILACS | ID: lil-550568

ABSTRACT

OBJETIVO: Artrodese do punho é uma cirurgia que deve ser sempre considerada em casos de patologias que alteram sua estrutura anatômica e funcional. Em geral os resultados são muito satisfatórios, principalmente no alívio da dor e na maioria das vezes a melhora funcional é considerável. Existem várias técnicas descritas, com variações no método de fixação interna e a maioria delas incluindo as articulações carpometacarpianas na fusão. O objetivo deste estudo é avaliar os resultados da artrodese do punho com uma técnica mais simples, mais biológica, menos dispendiosa e que não inclui as articulações carpometacarpianas. MÉTODOS: foram avaliados 15 pacientes (seis sequelas de traumatismo, quatro de artrite reumatoide, três de Kienbock grau IV, um de Preiser e um de pan-artrose). A técnica consistiu no uso de placa óssea do ilíaco e fixação com fios de Kirschner, sem incluir as articulações carpometacarpianas. RESULTADOS: A avaliação foi feita conforme o tempo de consolidação (93 por cento em sete semanas); movimentos dos dedos e de pronossupinação; da força de pinça e preensão; avaliação funcional pelo questionário DASH, da dor e satisfação dos pacientes. Em geral, os resultados foram semelhantes aos das outras técnicas mais agressivas e a não inclusão das articulações carpometacarpianas na artrodese não afetou o resultado final. CONCLUSÃO: A artrodese do punho com fixação através de fios de Kirschner e uso de placa óssea do ilíaco preservando as articulações carpometacarpianas dá resultado bom ou excelente, não inferior ao de outras técnicas descritas. Apresenta, porém uma grande vantagem sobre as demais: é menos agressiva, mais barata e não apresenta os inconvenientes do uso de placas e parafusos sujeitos a maiores complicações


OBJECTIVE: Wrist arthrodesis is a surgical procedure that should always be considered in pathologies where there is alteration of the anatomical and functional structures. In general, the results are very satisfactory, particularly for pain relief, and in the majority of cases, there is considerable functional improvement. Various techniques are described, with different methods of internal fixation, most of which include the carpometacarpal joints (CMJ) in the fusion. The objective of this study is to evaluate the results of wrist arthrodesis through a technique which is simpler, more biological, more inexpensive, and does not involve the carpometacarpal joints. METHODS: 15 patients with wrist arthrodesis were evaluated (6 with sequelae of trauma, 4 Rheumatoid Arthritis, 3 Kienbock's grade IV, 1 Preiser and 1 panarthrosis). The technique consisted of the use of an iliac bone plate and internal fixation with Kirschner wires, avoiding the carpometacarpal joints. RESULTS: The evaluation was based on consolidation time (93 percent in 7 weeks); movements of the fingers and pronosupination; pinch and grasp strength; functional evaluation through the DASH questionnaire, pain and patient satisfaction. In general, the results were similar to those of other, more aggressive techniques, and the non-inclusion of the carpometacarpal joints did not affect the final result. CONCLUSION: wrist arthrodesis with fixation using Kirschner wires and the use of an iliac bone plate, preserving the carpometacarpal joints, gives good or excellent results which are similar to those of other techniques described. However it presents major advantages over other methods: it is less aggressive, less expensive, and does not have the inconvenience and complications associated the use of plates and screws.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Bone Transplantation , Carpometacarpal Joints , Internal Fixators , Osteoarthritis , Wrist Injuries
17.
Rev. bras. ortop ; 44(5): 380-385, set.-out. 2009. ilus
Article in Portuguese | LILACS | ID: lil-531469

ABSTRACT

Os autores fazem uma ampla revisão da literatura destacando o emprego de hastes intramedulares flexíveis no tratamento de fraturas em crianças. Destacam o tratamento das fraturas diafisárias do fêmur e dos ossos do antebraço e enfatizam também a importância da abordagem não cirúrgica. A idade e o peso limite das crianças ainda não estão bem definidos para o emprego do método. A retirada de implantes tem destaque controverso na literatura, com tendência da permanência dos implantes.


The authors present a comprehensive review of the literature emphasizing the use of flexible intramedullary nails in the treatment of fractures in children, focusing the treatment of femoral shaft and forearm fractures and emphasizing the importance of the non-surgical approach. Children's age and weight threshold are not well defined for the use of the method. The removal of implants is a controversial matter in the literature, with a trend towards keeping the implants.


Subject(s)
Humans , Child , Fracture Fixation, Intramedullary , Fracture Fixation/methods , Internal Fixators , Orthopedic Fixation Devices , Stainless Steel , Titanium
18.
Coluna/Columna ; 8(1): 1-6, jan.-mar. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-538650

ABSTRACT

Avaliar a influência da reconstrução e fixação anterior no desempenho mecânico do fixador interno da coluna vertebral. MÉTODOS: foram formados três grupos experimentais de acordo com a reconstrução e fixação anterior: grupo I -sem suporte anterior; grupo II - com suporte anterior; grupo III - com suporte e fixação anterior. Os corpos de prova foram submetidos a ensaios mecânicos de flexo-compressão, flexão lateral e torção, realizados em máquina de universal de ensaios, tendo sido realizados dez ensaios para cada modalidade (flexo-compressão, flexão lateral e torção) em cada grupo experimental, perfazendo um total de 90 ensaios mecânicos. As propriedades mecânicas estudadas foram: o momento-fletor, o torque e a rigidez obtidos a partir da curva carga x deflexão de cada ensaio mecânico. RESULTADOS: observou-se que a colocação do suporte e da fixação anterior aumentou a resistência mecânica nos ensaios de flexo-compressão. Nos ensaios de flexão lateral observou-se aumento da resistência mecânica somente com a fixação anterior. CONCLUSÃO: nos ensaios de torção o suporte anterior e a fixação anterior não aumentaram a resistência mecânica do sistema de fixação vertebral.


Evaluation of the mechanical stability of the internal vertebral fixation through the influence of the anterior load bearing reconstruction and stabilization. METHODS: cylindrical woods blocks were utilized as test bodies and were stabilized by an internal fixation. Three experimental groups were set according to the anterior reconstruction and fixation: group I - without anterior support; group II - with anterior support and group III - with support and anterior fixation. In an universal assay machine the wood block underwent to flexion-compression, lateral flexion and torsion mechanical assays, until ten assays of each modality were performed (flexion-compression, lateral compression and torsion) in each experimental group, in a total of 90 mechanical assays. The studied mechanical proprieties were the flex moment, torsion moment and the stiffness, obtained through the load x deflection of each mechanical trial. RESULTS: it was observed that utilizing a support and anterior fixation there has been na increased mechanical stiffness in the flexion-compression mechanical assays. In the lateral flexion tests it was observed an increased rigidity only with the anterior fixation. CONCLUSION: with the torsion tests the anterior support and fixation did not increase the mechanical rigidity of the vertebral fixation system.


Evaluar la influencia de la reconstrucción y fijación anterior en el desempeño mecánico del fijador interno de la columna vertebral. MÉTODOS: fueron formados tres grupos experimentales de acuerdo com la reconstrucción y fijación anterior: grupo I- sin soporte anterior, grupo II- con soporte anterior y grupo III- con soporte y fijación anterior. Los cuerpos de prueba fueron sometidos a ensayos mecánicos de flexocompresión, flexión lateral y torción, realizados en la máquina universal de ensayos, habiéndose realizados 10 ensayos para cada modalidad (flexocompresión, flexión lateral y torción) en cada grupo experimental,con untotal de 90 ensayos mecánicos. Las propiedades mecánicas estudiadas fueron el momento-flexor, la torción y la rigidez obtenidas a partir de la curva carga x deflexión de cada ensayo mecánico. RESULTADOS: fue observado que la colocación del soporte y de la fijación anterior aumentaron la resistencia mecánica en los ensayos de flexo-compresión. En los ensayos de flexión lateral fue observado aumento de la resistencia mecánica solamente con la fijación anterior. CONCLUSIÓN: en los ensayos de torción, el soporte anterior y la fijación anterior no aumentaron la resistencia mecánica del sistema de fijación vertebral.


Subject(s)
Humans , Biomechanical Phenomena , Dystonia Musculorum Deformans , Internal Fixators , Orthopedic Fixation Devices , Spine , Stress, Mechanical
19.
Acta ortop. bras ; 17(5): 262-264, 2009. ilus
Article in English, Portuguese | LILACS | ID: lil-531713

ABSTRACT

OBJETIVO: Há uma variabilidade considerável na literatura no que tange ao tratamento ideal de fraturas do quinto metatarso. O objetivo deste estudo é apresentar os resultados da fixação cirúrgica de fraturas do quinto metatarso usando o parafuso Acutrak® em jogadores de futebol de elite. MATERIAL E MÉTODOS: Três casos de fratura do quinto metatarso em jogadores de futebol de elite são apresentados. A média de idade dos pacientes era de 24 anos (18-26 anos). Tratamos as três fraturas do quinto metatarso em jogadores de futebol de elite. Os casos em nosso estudo consistiam de uma fratura diafisiária do quinto metatarso e duas fraturas de Jones. As fraturas ocorreram durante a participação nos jogos. Aplicamos fixação interna utilizando um parafuso Acutrak® percutâneo sob anestesia local com o auxílio de um fluoroscópio. Os pacientes foram clinica e radiograficamente avaliados. RESULTADOS: O restabelecimento clínico foi obtido em 10 semanas após a cirurgia. A consolidação radiográfica ocorreu em 8 semanas de pós-operatório, sendo que os pacientes retornaram a seus níveis prévios de atividade em 11 semanas de pós-operatório. Não foi relatada nenhuma complicação pósoperatória. Não se observou nenhuma irritação de pele devido à ausência de cabeça do parafuso Acutrak®. CONCLUSÃO: Os resultados sugerem que Acutrak® pode ser usado em jogadores de futebol com fraturas do quinto metatarso. Apesar de fatores como facilidade de implante, o custo e a resistência a inclinação também devem ser considerados.


OBJECTIVE: There is considerable variability in the literature concerning the optimal treatment of fifth metatarsal fracture. The purpose of this study is to report the outcome of surgical fixation of fifth metatarsal fractures using Acutrak® screw in elite football players. MATERIAL AND METHOD: Three cases of fifth metatarsal fracture in elite football players. The mean age was 24 years old (18-26 years). We treated three fifth metatarsal fractures in elite football players. The cases in our study consisted of one diaphyseal fifth metatarsal fracture and two Jones fractures. The fractures had been occurred during sports participation. We applied internal fixation using a percutaneous Acutrak® screw under local anesthesia with the aid of fluoroscopy. The patients were clinically and radiographycally evaluated. RESULTS: Clinic healing was obtained at 10 weeks postoperatively. Radiographic consolidation occurred at 8 weeks postoperatively and the patients returned to pre-injury activity levels at 11 weeks postoperatively. No postoperative complication was seen. No skin irritation due to a headless screw of Acutrak® was observed. CONCLUSION: The result suggested that Acutrak® may be used in elite football players with fifth metatarsal fractures. In spite of factors such as ease of implementation, cost and resistance to bending also need to be considered.


Subject(s)
Humans , Male , Adult , Bone Screws , Fractures, Bone , Fractures, Bone , Soccer/injuries , Metatarsal Bones/surgery , Metatarsal Bones/injuries , Athletic Injuries , Fracture Fixation
20.
Rev. bras. ortop ; 43(8): 351-356, ago. 2008. ilus, graf
Article in Portuguese | LILACS | ID: lil-494105

ABSTRACT

OBJETIVO: Estudar as alterações agudas da interface entre os parafusos e o tecido ósseo vertebral, considerando o diâmetro do orifício-piloto em relação ao diâmetro interno do parafuso. MÉTODOS: O estudo foi realizado em carneiros e a segunda vértebra cervical selecionada para o estudo. Foram utilizados parafusos corticais de 3,5mm de diâmetro externo (2,4mm de diâmetro interno) e 14mm de comprimento. Foram formados quatro grupos experimentais: 1) orifício-piloto de 2,0mm e colocação do parafuso de 3,5mm; 2) orifício-piloto de 2,5mm e colocação do parafuso de 2,5mm; 3) orifício-piloto de 2mm sem colocação do parafuso; e 4) orifício-piloto de 2,5mm sem colocação do parafuso. RESULTADOS: O grupo 1 (orifício-piloto menor do que o diâmetro interno do parafuso) apresentou maior densidade óssea no interior da rosca do implante e maior densidade óssea na área em espelho do que o grupo 2 (orifício-piloto maior que o diâmetro interno do parafuso). A superfície de contato entre o tecido ósseo e o implante foi maior no grupo 2 em relação ao grupo 1. A comparação da densidade óssea na área em espelho entre os grupos com e sem implante (1 e 3) e (2 e 4) mostrou que a densidade óssea era maior nos grupos com o implante. Não foi observada diferença estatística entre as comparações dos grupos experimentais. CONCLUSÃO: A utilização de orifício-piloto de menor diâmetro em relação ao diâmetro interno do parafuso apresentou tendência a provocar maior compactação do osso ao redor do implante.


OBJECTIVE: To study acute changes in the interface between screws and vertebral bone tissue, considering the pilot hole diameter in relation to the inner diameter of the screw. METHODS: The study was carried out in sheep, and the second cervical vertebra was selected for the study. Cortical screws were used, with 3.5 mm of external diameter (2.4 mm of inner diameter) and 14 mm in length. Four experimental groups were formed: 1 2.0 mm pilot hole and placement of 3.5 mm screw; 2 - 2.5 mm pilot whole and placement of 2.5 mm screw; 3 - 2 mm pilot hole with no screw placement; and 4 2.5 mm pilot whole with no screw placement. RESULTS: Group 1 (pilot hole smaller than the inner diameter of the screw) presented more bone density inside the implant thread and more bone density in the mirror area than group 2 (pilot hole larger than the inner diameter of the screw). The contact surface between bone tissue and the implant was larger in group 2 when compared to group 1. The comparison of bone density in the mirror area among the groups with and without screw placement (1 and 3) and (2 and 4) showed that bone density was greater in the groups with screw placement. No statistical differences were seen among the comparisons of the experimental groups. CONCLUSION: The use of a pilot hole with a smaller diameter than the inner diameter of the screw tended to cause more bone compaction around the screw.


Subject(s)
Animals , Bone Screws , Internal Fixators , Orthopedic Fixation Devices , Spine , Sheep
SELECTION OF CITATIONS
SEARCH DETAIL